With a total capacity of 8,000 l/h the PURION 2500 90W Dual An extremely large UV-C disinfection system, which is mainly used in hotels and large apartment buildings. Technically, this system is based on two normal PURION 2500 90W that are switched in series. This doubles the length of the water in the system and more water can be disinfected accordingly. The procedure of the UV-C disinfection specifically dissolves the DNA connections of the bacteria and viruses, which means that these are considered killed. The taste and smell remains unchanged and the composition of the water remains. With this maintenance low and reliable UV-C disinfection system, the lamps can be conveniently changed while operating. Such a change rarely occurs because the lamps have a very high lifespan. The PURION 2500 90W Dual gives customers and tenants the certainty of drinking clean and germ -free water.
This system is designed for a voltage range of 85-264V by a long-voltage operating operating device and can thus be used in many different countries. The system is equipped with a euro plug and can also be used for other types of plugs with an adapter (not included).
This system is a flow system. It needs a low, permanent water current, because the UV-C lamp heats the water so strongly that the lifespan of the UV-C lamp can be affected.
The UV-C lamp has a natural drop in performance over the duration of its lifetime. We guarantee that the lamp has reached the promised flow output after 10,000 hours. After this time, the lamp must be changed, the lamp runtime knife and the service life monitoring (OTC) signal the right time. The hours in which the lamp is switched on are counted and the values are output via an LED display. A green LED shines up to 9,000 hours, between 9,000 and 10,000 hours the pre -alarm is displayed with a yellow LED and after 10,000 hours a red LED lights up. So the right time is not missed to change the lamp.
This UV-C disinfection system of PURION met all technical requirements of the drinking water regulation. The stainless steel used 1,4571 also becomes in the food industry and thus fulfills the norm. The required UV-C dose of 400 J/m² is performed with a UV-C trans mission of 90% T1 cm in compliance with the prescribed, maximum flow rate. This UV-C system thus reaches a disinfection rate of 99.99%that the legislator prescribes. For trademark protection law reasons, this system has no DVGW-Ktique, so in individual cases it must be clarified with the health department whether the UV-C disinfection system can be used.
In addition to the system, this bundle includes another replacement lamp, the right assembly tile and a service kit for intensive cleaning.