PURION 1000 110 - 240 V AC OTC

Regular price 539,00€
Sale price Regular price

Available monitoring levels for this product

Our UV-C systems offer various monitoring levels tailored to every individual requirement.

Without monitoring level

Without monitoring level

  • Manual inspection required
  • Can be used independently of technology
With lifetime monitoring

With lifetime monitoring

  • Automatic operating time measurement of the UV-C lamp
  • LED indicators for status and pre-alarms (green/yellow/red)
  • Easy operation without manual counting
Bestseller
With sensor monitoring

With sensor monitoring

  • Permanent monitoring of UV-C performance
  • LED indicators for performance intensity (green/yellow/red)
  • Immediate detection of contamination or performance loss
  • Optimal control without additional effort
With solenoid valve

With solenoid valve

  • Permanent monitoring of UV-C performance
  • LED indicators for intensity (green/yellow/red)
  • Automatic shutdown in the event of performance loss
  • De-energized solenoid valve protects even during a power outage
  • Maximum efficiency and user-friendliness

With rising water prices and expensive connection fees, self-sufficiency with drinking water is more than just an alternative. One of the biggest hurdles in this independence is the targeted disinfection of water. Bacteria, such as the often headline-making E-Coli or other germs and viruses, make perfect disinfection absolutely necessary for every household. The PURION 1000 is not only ideally suited for a single-family home with up to four people, but it is also extremely energy-efficient with 17W. The treatment with UV-C light does not affect the smell or taste of the water. The compact design of the PURION 1000 makes it very easy to integrate into existing water circuits. Due to these advantages, the PURION 1000 is the right choice to protect against rising prices and to take care of the health of the whole family.

Thanks to a wide voltage ballast, this system is designed for a voltage range of 85-264V and can therefore be used in many different countries. The system is equipped with a Euro plug and can also be used for other plug types with an adapter (not included).

This UV-C disinfection system from PURION meets all the technical requirements of the drinking water regulation. The stainless steel 1.4571 used is also used in the food industry and thus meets the standard. By adhering to the prescribed maximum flow rate, the required UV-C dose of 400 J/m² is achieved at a UV-C transmission of 90% T1 cm. Thus, this UV-C system achieves a disinfection rate of 99.99%, as required by law. For trademark protection reasons, this system does not have a DVGW certificate, so in individual cases, it must be clarified with the health department whether the UV-C disinfection system can be used. 

Monitoring level of this system: Lifetime monitoring

The UV-C lamp has a natural performance drop over its lifetime. We guarantee you that the lamp will have reached the promised flow performance after 10,000 hours. After this time, the lamp must be replaced, and the lamp runtime meter and lifetime monitoring (OTC) signal the right time. The hours the lamp is on are counted, and the values are displayed via an LED display. Up to 9,000 hours, a green LED lights up, between 9,000 and 10,000 hours, the pre-alarm is indicated with a yellow LED, and after 10,000 hours, a red LED lights up. Thus, the right time for lamp replacement is not missed.

More products compared with PURION 1000 110 - 240 V AC OTC

More products compared with PURION 1000 110 - 240 V AC OTC
PURION 1000 110 - 240 V AC OTC This product
Power consumption
Water flow rate
Dimensions
Safety level
Minimum flow rate
Recommended number of people
Pre-filtration
Spare parts included
Pump function
Price 539,00€639,00€639,00€2.299,00€649,00€

Frequently asked questions about PURION 1000 110 - 240 V AC OTC

Here you will find answers to the most frequently asked questions about our product.

A UV-C disinfection system is always the last link in a water treatment chain, as the path to the extraction point should be kept as short as possible. In particular, water filters offer ideal conditions for colonization by bacteria. The freshly disinfected water would therefore become contaminated again if it were to continue through the drinking water circuit after passing through the UV-C system. Pressure tanks should also always be installed before the UV-C systems.

Every UV-C lamp has a technically induced drop in UV-C performance. The manufacturer guarantees that the system still reaches 60% UV-C performance after 10,000 hours. The specified data for the systems always refer to this 60% performance. However, after 10,000 hours of operation, the performance drop continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C performance for an optimal disinfection result.

Lifetime monitoring is recommended for all users who do not leave the system permanently on. A lamp replacement every 10,000 hours is recommended because the manufacturer does not guarantee performance beyond that, i.e., the amount of UV-C radiation dose necessary for safe disinfection.

If no water is drawn during the operation of the lamps, the water inside the system heats up. In the 10W, 17W, and 36W systems, this effect is negligible as the water temperature does not rise above 40°C. However, if the water is heated more than 40°C, as is possible with the 48W and 90W variants, the lifespan of the lamp can be negatively affected. Therefore, it is recommended to ensure a constant water flow in these systems.

The UV system should be permanently switched on for various technical reasons:
1.) The UV system takes about 1 minute to reach full performance.
2.) Igniting the lamp requires about as much energy as operating it for two hours.
3.) Each on and off cycle reduces the lifespan.

The important factor here is not the average daily water consumption, but the maximum withdrawal amounts that can occur. Therefore, the correct drinking water system is determined by the existing extraction stations and the number of people in the house. A fully opened faucet has a capacity of 300 to 500 liters per hour. In case of doubt, the next stronger system should be used.

No, we recommend flow reactors because the maximum distance between the water to be disinfected and the UV-C lamp is precisely defined. A tank disinfection system can only ensure complete disinfection if it has a previously calculated circulation. Furthermore, flow reactors are significantly more efficient.

A UV-C sensor is used to measure the emitted UV-C performance directly at the lamp. This ensures much higher safety for the user, as a performance drop is directly signaled. This can be due to poor transmission or a natural performance drop of the lamp by reaching the recommended maximum operating time of 10,000 hours.

This should be clarified with the health department in case of doubt. For this purpose, the operating certificate for the systems is available in the download area of the respective product pages of this online shop. We are also happy to advise you personally on this topic. Alternatively, we also offer a UV system certified according to both DVGW and Ö-Norm with the PURION DVGW ZERT.

Made in Germany

Our products stand for the highest quality and are manufactured with precision in Germany.

30 days free returns

You can return your order free of charge within 30 days without any hassle.

Free customer consultation

Our experienced team is always available to provide you with free advice and assistance.