With the help of the PURION On the basis of the physical principle of the UV-C disinfection, 1000 h can be steered in a hot water cycle. With this type of disinfection, the water is illuminated with UV-C light, which dissolves DNA connections. Legionella are reliably killed, better and, above all, more efficient than with other procedures. Especially in power-saving systems, such as the heating of water by a solar panel with heat exchangers, borderline temperature ranges of 40-50 ° C are reached in which legionella feel very comfortable. The popular but extremely expensive trick of heating the water to 70 ° C has little sense here, since the electricity saving by the solar panel becomes superfluous. In order to avoid this expensive solution, the UV-C disinfection is ideal. A very powerful lamp with extraordinarily high lifespan can also save money here. Even an operation in single -family houses with up to 6 people pays off. With the PURION 1000 hours can be sure that you do not attract disinfectant disease from legionella when showering or bathing.
This system is designed for a voltage range of 85-264V by a long-voltage operating operating device and can thus be used in many different countries. The system is equipped with a euro plug and can also be used for other types of plugs with an adapter (not included).
The UV-C lamp has a natural drop in performance over the duration of its lifetime. We guarantee that the lamp has reached the promised flow output after 8,000 hours. After this time, the lamp must be changed, the lamp runtime knife and the service life monitoring (OTC) signal the right time. The hours in which the lamp is switched on are counted and the values are output via an LED display. A green LED shines up to 7,000 hours, between 7,000 and 8,000 hours the pre -alarm is displayed with a yellow LED and after 8,000 hours a red LED lights up. So the right time is not missed to change the lamp.
This UV-C disinfection system of PURION met all technical requirements of the drinking water regulation. The stainless steel used 1,4571 also becomes in the food industry and thus fulfills the norm. The required UV-C dose of 400 J/m² is performed with a UV-C trans mission of 90% T1 cm in compliance with the prescribed, maximum flow rate. This UV-C system thus reaches a disinfection rate of 99.99%that the legislator prescribes. For trademark protection law reasons, this system has no DVGW-Ktique, so in individual cases it must be clarified with the health department whether the UV-C disinfection system can be used.
In addition to the system, this bundle includes another replacement lamp, the right assembly tile and a service kit for intensive cleaning.