- PURION IBC DN150 17W SPL BS
- PURION IBC DN150 17W SPL BS OTC
- PURION IBC DN150 17W SPL BS 12 V/24 V
- PURION IBC DN150 17W SPL BS OTC 12 V/24 V
- PURION IBC DN150 36W SPL BS
- PURION IBC DN150 36W OTC SPL BS
- PURION IBC DN150 48W SPL BS
- PURION IBC DN150 48W OTC SPL BS
- PURION IBC DN150 90W SPL BS
- PURION IBC DN150 90W OTC SPL BS
-
- PURION IBC DN225 17W SPL BS
- PURION IBC DN225 17W SPL BS OTC
- PURION IBC DN225 17W SPL BS 12 V/24 V
- PURION IBC DN225 17W SPL BS OTC 12 V/24 V
- PURION IBC DN225 36W SPL BS
- PURION IBC DN225 36W OTC SPL BS
- PURION IBC DN225 48W SPL BS
- PURION IBC DN225 48W OTC SPL BS
- PURION IBC DN225 90W SPL BS
- PURION IBC DN225 90W OTC SPL BS
-
- PURION IBC Universal 17W SPL BS
- PURION IBC Universal 17W SPL BS OTC
- PURION IBC Universal 17W SPL BS 12V/24V
- PURION IBC Universal 17W SPL BS OTC 12V/24V
- PURION IBC Universal 36W SPL BS
- PURION IBC Universal 36W OTC SPL BS
- PURION IBC Universal 48W SPL BS
- PURION IBC Universal 48W OTC SPL BS
- PURION IBC Universal 90W SPL BS
- PURION IBC Universal 90W OTC SPL BS

We are happy to advise you!
Do you have questions or need individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
Description
The compact design allows for easy and tool-free lamp removal and replacement, for example, at the end of the lamp's service life. For cleaning purposes, the quartz immersion tube can also be disassembled and assembled without tools. The water to be treated flows through the housing and is specifically guided along the quartz immersion tube, in which the lamp is mounted. The small water film thickness of only 7.5 mm, meaning the distance between the UV light exit at the quartz tube surface and the inner wall of the housing, guarantees optimal penetration of the water by the UV light.
Available monitoring levels for this product
Our UV-C systems offer various surveillance levels that are tailored to every individual requirement.

without monitoring level
- Manuelle Inspektion erforderlich
- Unabhängig von Technik nutzbar
ab 7 158 kr
Selected
With lifespan monitoring
- Automatic term measurement of the UV-C lamp
- LED displays for status and pre-alarms (green/yellow/red)
- Easy operation without manual counting
ab 8 723 kr
Zum Produkt
With sensor monitoring
- Permanent monitoring of UV-C performance
- LED indicators for performance intensity (Green/Yellow/Red)
- Immediate detection of contamination or performance drop
- Optimal control without additional effort
ab 12 373 kr
Zum Produkt
With solenoid valve
- Permanent monitoring of UV-C performance
- LED indicators for intensity (Green/Yellow/Red)
- Automatic shutdown in case of performance drop
- Powerless solenoid valve protects even in case of power failure
- Maximum efficiency and user-friendliness
ab 20 848 kr
Zum ProduktTechnical data
Here you will find all technical specifications.
Connection | R 1" |
Reactor | Stainless steel 1.4571 |
UVC Transmission | 90% T1 cm |
Plant type | PURION 2000 |
Weight | 2.8 kg |
Poetry | FPM |
Water temperature | 8 °C to 40 °C |
Electrical connection | 110 - 240 V, 50 - 60 Hz |
Dosis | 400 J/m² |
Service life of spotlights | 10,000 h |
Performance | 48 W |
Protection | 10 A |
Throughput | 2,000 l/h drinking water |
Flange distance | 500 mm |
Number of spotlights | 1 |
Dimensions (L x W in mm) | 578 x 42 |

We are happy to advise you!
Do you have questions or would like individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
+49 3641 327 9697 info@uvconcept.comDownloads
Technical documents for download
Scope of delivery
What is included in the delivery
- UV lamp (48 W)
- User manual
Frequently asked questions
Here you will find answers to the most frequently asked questions about our product.
The pool systems from the company PURION are not exposed to overheating problems if the UVC system is turned on but no water flow occurs.
No. We recommend always operating the UV system in combination with the pump, which utilizes the full flow for disinfection. Since the system has a relatively large diameter, there is no failure if the pump is defective and there is no water flow with the UV lamp turned on.
For optimal effect, we recommend circulating the entire pool content at least three times daily. However, the system should be in operation for at least 8 hours daily to ensure sufficient ventilation and filtration. The circulation rate depends on the performance of the pump and sand filter used. The net performance of the pump can be reduced by the lengths and heights of the pipes to be overcome. Also interesting: In our compact systems, the pump, sand filter, and UVC system are ideally matched and pre-assembled.
There is a simple calculation for this: the pool content should flow through the UV-C system at least three times a day to kill a large portion of the algae through proper mixing. If algae growth is increased, e.g., during phases of extreme sunlight or after heavy rainfall or a thunderstorm, we recommend temporarily setting the circulation rate to four times. Regardless of the circulation rate, we recommend having the system in operation for at least 8 hours daily to allow sufficient ventilation and filtration.
By considering all three basic recommendations for using a UV-C system in the pool area, the pool can be operated completely without chlorine. The occasional use of a biological flocculant may be advisable. However, our high-quality UV-C lamps allow a combination of chlorine and UV-C, as no ozone is produced, which would react with chlorine.
The high-quality UV-C lamps from the brand PURION are durable and very powerful. They produce a very high UV-C content. The lamps we use in the pool area are also used in other systems for drinking water treatment. The UV lamps used do not emit radiation below 250nm, which excludes the formation of toxic ozone. Thus, the systems from PURION can be used in combination with other treatment methods that use chlorine, for example.
No, from our perspective, ozone should not be used in the pool area under any circumstances. Ozone is highly toxic. Excess ozone must be laboriously destroyed again, and it is often unclear how much ozone is left. Furthermore, ozone reacts with chlorine, significantly reducing the effectiveness of both methods. Cheaply produced UV lamps often emit radiation below 250nm, which can form ozone. This is excluded in the systems from PURION.
Each UV-C lamp exhibits a technically induced decline in UV-C output. The manufacturer guarantees that the system will still achieve 60% UV-C output after 10,000 hours. The specified data for the systems always refer to this 60% output. However, after 10,000 hours of operation, the decline in output continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C output for optimal disinfection results.
A lifespan monitoring is recommended for all users who do not keep the system permanently switched on. It is recommended to replace the lamp every 10,000 hours, as the manufacturer does not guarantee the performance, i.e., the amount of UV-C radiation dose necessary for safe disinfection, beyond that.
Suitable accessories for PURION 2000 Basic








Related posts about the product

Guide to UVC Disinfection: Everything You Need to Know - Drinking Water
Experience the benefits of UVC disinfection: chemical-free, effective, and sustainable – for germ-free and safe drinking water in every household.
Everything important about shipping & purchase
Do you Brauchen Sie Hilfe? We are here for you!