Unsere Produkte

WIR BERATEN SIE GERN!

Sie haben Fragen oder wünschen eine individuelle Beratung?

info@uvconcept.com

+49 3641 327 9697

ANFRAGE
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra
PURION 2500 H DUAL Extra

PURION 2500 H DUAL Extra

Extra - with sensor monitoring
€2.352,93

*inkl. ges. MWSt

Lieferzeit 1-2 Tage

Wähle die passende Überwachungsstufe:

Beschreibung

Many headlines in recent months and years repeatedly refer to the problem of legionella. These bacteria feel very comfortable especially in hot water circuits, which led to the fact that in some apartments showering was prohibited by the health department. In this situation, which is very annoying for tenants, the PURION 2500 H can provide relief. The landlord is saved a lot of costs if he uses this system instead of heating the water by 20°C to 70°C at extremely high cost. The principle of UV-C disinfection is based on the fact that the DNA of the Legionella bacteria is dissolved and these are killed absolutely reliably. Low energy costs and comparatively low replacement lamp costs are easy on the wallet. Due to the special design, the UV-C lamp of this system can be replaced during operation, although this will rarely be necessary due to its long service life. With a capacity of 5,000 l/h, this UV-C system can also supply larger apartment buildings with legionella-free water without any problems.

Due to a wide voltage ballast, this system is designed for a voltage range of 85-264V and can thus be used in many different countries. The system is equipped with a Euro plug and can also be used with an adapter (not included) for other types of plugs.

This UV-C disinfection system from PURION fulfills all technical requirements of the drinking water ordinance. The used stainless steel 1.4571 is also used in the food industry and therefore meets the standard. In compliance with the prescribed maximum flow rate, the required UV-C dose of 400 J/m² is achieved with a UV-C transmission of 90% T1 cm. This UV-C system thus achieves a disinfection rate of 99.99%, which is required by law. For trademark protection reasons, this system does not have a DVGW certificate, so in individual cases it must be clarified with the health authority whether the UV-C disinfection system can be used.

Technische Daten

HerstellerPURION GmbH
ReaktorEdelstahl 1.4571
Anschluss AußengewindeR 1"
Durchsatz10.000 l/h drinking water
DichtungFPM
Dimensionen (L x B in mm)928 x 42
Flanschabstand850 mm
Gewicht6 kg
Strahlernutzungsdauer8.000 h
Anzahl der Strahler2
Dosis400 J/m²
Maximale Temperatur 90 °C
GehäuseschutzartIP 65
Elektrischer Anschluss110 - 240 V, 50 - 60 Hz
Leistung106 W (2x)
Absicherung10 A
Wassertemperatur2 °C bis 90 °C

Download

Zum Download stehende Dokumente

Datenblatt 1:Herunterladen

Lieferumfang

- UV disinfection system
- 2x UV lamp (106 W)
- Instruction manual

Zubehör

  • PURION service kit
    €24,60
  • PURION immersion pipe system T2500/2501
    €96,29
  • PURION UVC lamp 106 W
    €159,99
  • PURION mounting set Duals type 1
    €97,36

FAQ

Häufig gestellte Fragen

Can the system overheat?

With the hot water systems Purion 1000 h and 2500 h, there is no risk of overheating because the lamps are designed for these temperature ranges.

How do I know which UV-C system is the right one for me?

The hot water systems are installed directly into the circulation, the maximum flow speed is therefore directly dependent on the performance of the circulation pump. For houses of 5 residential units, we recommend the Purion 2500 H. Our customer service will be happy to determine the ideal dimensioning of the necessary system.

Why does the UV-C lamp have to be changed after 8,000 hours (only for hot water systems) or 10,000h (for all other systems), even though it still works?

Each UV-C lamp has a technical drop in the UV-C performance. The manufacturer guarantees that the system will reach 60% UV-C output after 10,000 hours. The specified data on the systems always refer to this 60% performance. From a term of 10,000 hours, however, the drop in performance continues to increase, but the lamp still works, but there is no longer enough UV-C output for an optimal disinfection result.

Can these systems be reliably used to eliminate legionella?

Special amalgam lamps are installed in Purion's H series, which have a high effectiveness in hot water. As a result, legionella can also be killed in larger water flows.

What do I need a sensor for and to what extent does it differ from the life of life?

A UV-C sensor is used to measure the UV-C output released directly on the lamp. This ensures significantly higher security for the user, since a drop in performance is directly signaled. This can be too bad transmission or a natural drop in performance of the lamp due to the eore of the recommended maximum operating time of 10,000 hours.

Which UV-C dose is used?

We use a UV-C dose of 400 J/m² for safe disinfection. This performance is sufficient to achieve a disinfection quota of 99.99% in compliance with the given flow rate and transmission. Thus, water from a tank or container can be prepared precisely.

When do I need a life of life?

A service life monitoring is recommended for all users who do not permanently let the system switch on. A change of the lamp is recommended every 10,000 hours, since the manufacturer also does not guarantee the performance, i.e. the amount of UV-C radiation dose required for safe disinfection.

Sicherheit & Qualität

HERGESTELLT IN
DEUTSCHLAND

30 TAGE KOSTENLOSE
PRODUKTRÜCKGABE

KOSTENFREIE
KUNDENBERATUNG

OFFIZIELLER PURION
HÄNDLER

Schneller Versand

Flexible Zahlung