Unsere Produkte

WIR BERATEN SIE GERN!

Sie haben Fragen oder wünschen eine individuelle Beratung?

info@uvconcept.com

+49 3641 327 9697

ANFRAGE
PURION 1000 H ESM
PURION 1000 H ESM
PURION 1000 H ESM
PURION 1000 H ESM
PURION 1000 H ESM
PURION 1000 H ESM
PURION 1000 H ESM
PURION 1000 H ESM

PURION 1000 H ESM

Ultra - with solenoid valve
€1.699,00

*inkl. ges. MWSt

Lieferzeit 1-2 Tage

Wähle die passende Überwachungsstufe:

Beschreibung

The PURION 1000 H can be used to specifically kill legionella in a hot water circuit based on the physical principle of UV-C disinfection. In this type of disinfection, the water is illuminated with UV-C light, which dissolves DNA compounds. Legionella are thus reliably killed, better and above all more efficiently than with other methods. Especially in power-saving systems, such as when water is heated by a solar panel with heat exchanger, borderline temperature ranges of 40-50°C are reached, in which Legionella feel very comfortable. The popular but extremely expensive trick of heating the water to 70°C makes little sense here, as the electricity savings from the solar panel are thus rendered superfluous. To avoid this expensive solution, UV-C disinfection is the obvious choice. Due to a very energy-saving lamp with an extraordinarily long service life, additional money can be saved here. Even an application in single family houses with up to 6 persons pays off. With the PURION 1000 H you can be sure not to contract any disinfection disease caused by legionella while showering or bathing.

Due to a wide voltage ballast, this unit is designed for a voltage range of 85-264V and can thus be used in many different countries. The system is equipped with a Euro plug and can also be used with an adapter (not included) for other types of plugs.

This UV-C disinfection system from PURION fulfills all technical requirements of the drinking water ordinance. The used stainless steel 1.4571 is also used in the food industry and therefore meets the standard. In compliance with the prescribed maximum flow rate, the required UV-C dose of 400 J/m² is achieved with a UV-C transmission of 90% T1 cm. This UV-C system thus achieves a disinfection rate of 99.99%, which is required by law. For trademark protection reasons, this system does not have a DVGW certificate, so in individual cases it must be clarified with the health authority whether the UV-C disinfection system can be used.

Technische Daten

HerstellerPURION GmbH
ReaktorEdelstahl 1.4571
Anschluss AußengewindeR 1"
Durchsatz1.500 l/h drinking water
DichtungFPM
Dimensionen (L x B in mm)420 x 42
Flanschabstand340 mm
Gewicht2 kg
Strahlernutzungsdauer8.000 h
Anzahl der Strahler1
Dosis400 J/m²
Maximale Temperatur 90 °C
GehäuseschutzartIP 65
Elektrischer Anschluss110 - 240 V, 50 - 60 Hz
Leistung42 W
Absicherung10 A
Wassertemperatur2 °C bis 90 °C

Download

Zum Download stehende Dokumente

Datenblatt 1:Herunterladen

Lieferumfang

- UV disinfection system
- UV lamp (42 W)
- Instruction manual

Zubehör

  • PURION mounting set singles type 1
    €25,67
  • PURION service kit
    €24,60
  • PURION UVC Lamp 42 W
    €110,99

FAQ

Häufig gestellte Fragen

Can the system overheat?

With the hot water systems Purion 1000 h and 2500 h, there is no risk of overheating because the lamps are designed for these temperature ranges.

How do I know which UV-C system is the right one for me?

The hot water systems are installed directly into the circulation, the maximum flow speed is therefore directly dependent on the performance of the circulation pump. For houses of 5 residential units, we recommend the Purion 2500 H. Our customer service will be happy to determine the ideal dimensioning of the necessary system.

Why does the UV-C lamp have to be changed after 8,000 hours (only for hot water systems) or 10,000h (for all other systems), even though it still works?

Each UV-C lamp has a technical drop in the UV-C performance. The manufacturer guarantees that the system will reach 60% UV-C output after 10,000 hours. The specified data on the systems always refer to this 60% performance. From a term of 10,000 hours, however, the drop in performance continues to increase, but the lamp still works, but there is no longer enough UV-C output for an optimal disinfection result.

Can these systems be reliably used to eliminate legionella?

Special amalgam lamps are installed in Purion's H series, which have a high effectiveness in hot water. As a result, legionella can also be killed in larger water flows.

What do I need a sensor for and to what extent does it differ from the life of life?

A UV-C sensor is used to measure the UV-C output released directly on the lamp. This ensures significantly higher security for the user, since a drop in performance is directly signaled. This can be too bad transmission or a natural drop in performance of the lamp due to the eore of the recommended maximum operating time of 10,000 hours.

Which UV-C dose is used?

We use a UV-C dose of 400 J/m² for safe disinfection. This performance is sufficient to achieve a disinfection quota of 99.99% in compliance with the given flow rate and transmission. Thus, water from a tank or container can be prepared precisely.

When do I need a life of life?

A service life monitoring is recommended for all users who do not permanently let the system switch on. A change of the lamp is recommended every 10,000 hours, since the manufacturer also does not guarantee the performance, i.e. the amount of UV-C radiation dose required for safe disinfection.

Sicherheit & Qualität

HERGESTELLT IN
DEUTSCHLAND

30 TAGE KOSTENLOSE
PRODUKTRÜCKGABE

KOSTENFREIE
KUNDENBERATUNG

OFFIZIELLER PURION
HÄNDLER

Schneller Versand

Flexible Zahlung