Beschreibung

With rising water prices and expensive connection fees, self-supply of drinking water is more than a mere alternative. One of the biggest hurdles in this self-sufficiency is the specific disinfection of water. Bacteria, such as the e-coli that often makes the headlines, or other germs and viruses make perfect disinfection absolutely essential for every household. The PURION 1000 is not only ideal for a single-family home with up to four people, but is also extremely energy-efficient at 17W. Due to the treatment with UV-C light, the water is neither affected in smell nor in taste. The compact design of the PURION 1000 makes it very easy to integrate into existing water circuits. These advantages make the PURION 1000 the right choice to protect against rising prices and to take care of the health of the whole family.

With the help of the 12V connection, this unit can be integrated into various power circuits. Examples are accumulators and photovoltaic panels or the electric circuit of a motor home. Especially for photovoltaic panels, a battery is indispensable, because the UV-C lamp must be supplied constant 12V voltage.

This UV-C disinfection system from PURION meets all technical requirements of the drinking water ordinance. The used stainless steel 1.4571 is also used in the food industry and therefore meets the standard. In compliance with the prescribed maximum flow rate, the required UV-C dose of 400 J/m² is achieved with a UV-C transmission of 90% T1 cm. This UV-C system thus achieves a disinfection rate of 99.99%, which is required by law. For trademark protection reasons, this system does not have a DVGW certificate, so in individual cases it must be clarified with the health authority whether the UV-C disinfection system can be used.

Technische Daten

HerstellerPURION GmbH
ReaktorEdelstahl 1.4571
Anschluss AußengewindeR 1"
Durchsatz1000 l/h drinking water
DichtungFPM
Dimensionen (L x B in mm)420 x 42
Flanschabstand340 mm
Gewicht2 kg
Strahlernutzungsdauer10.000 h
Anzahl der Strahler1
Dosis400 J/m²
Maximale Temperatur 40 °C
GehäuseschutzartIP 65
Elektrischer Anschluss12 V / 24 V, 50 - 60 Hz
Leistung17 W
Absicherung10 A
Wassertemperatur2 °C bis 40 °C

Download

Zum Download stehende Dokumente

Datenblatt 1:Herunterladen

Lieferumfang

- UV disinfection system
- UV lamp (17 W)
- Instruction manual

Zubehör

  • PURION UVC lamp 17 W
    €62,99
  • PURION service kit
    €24,60
  • PURION mounting set singles type 1
    €25,67
  • PURION immersion pipe system T1000
    €81,31

FAQ

Häufig gestellte Fragen

At what point does the UV-C system have to be installed in the drinking water cycle?

A UV-C disinfection system is always the last link in a water treatment chain, since the path to the withdrawal point should be kept as low as possible. Water filters in particular offer ideal conditions for settlement by bacteria. The freshly disinfected water would therefore germinate again if it would continue through the drinking water cycle after going through the UV-C system. Printing boilers should always be installed in front of the UV-C systems.

When do I need a life of life?

A service life monitoring is recommended for all users who do not permanently let the system switch on. A change of the lamp is recommended every 10,000 hours, since the manufacturer also does not guarantee the performance, i.e. the amount of UV-C radiation dose required for safe disinfection.

Does the system automatically switch on the water flow?

The UV system should be permanently switched on for various technical reasons:
1.) The UV system needs about 1 minute to achieve full performance.
2.) When igniting the lamp, as much energy is required as for operation over two hours.
3.) Each on and off cycle is at the expense of the service life.

How do I know which UV-C system is the right one for me?

The correct dimensioning of the systems is not based on the maximum daily consumption but the expected maximum point of time and is therefore dependent on the performance of the pump.

What should be considered when installing 12V DC and 24V DC systems?

It should be noted that no power supplies with powdered voltage are used, which means that the system can suffer irreparable damage.

Can the system be operated with photovoltaic panels?

Yes, that is possible. However, the use of a battery is always recommended to ignite the lamp. In addition, a solar controller should always be used.

Do you recommend fuel germination?

No, we advise flow reactors, as the maximum distance between the water to disinfect and the UV-C lamp is precisely defined. A tank collision system can only ensure a complete disinfection if it has a previously calculated revolution. In addition, flow reactors are much more efficient.