A PURION 2500 90 W PRO basic unit with connected lamp, specially designed for disinfection purposes.
Brand name: PURION GmbH.

PURION 2500 90 W PRO Basic

Regular price 3.168,00 zł
Sale price Regular price

Verfügbare Überwachungsstufen für dieses Produkt

Unsere UV-C-Anlagen bieten verschiedene Überwachungsstufen, die auf jede individuelle Anforderung abgestimmt sind.

Ohne Überwachungsstufe

Ohne Überwachungsstufe

  • Manuelle Inspektion erforderlich
  • Unabhängig von Technik nutzbar
Mit Lebensdauerüberwachung

Mit Lebensdauerüberwachung

  • Automatische Laufzeitmessung der UV-C-Lampe
  • LED-Anzeigen für Status und Voralarme (Grün/Gelb/Rot)
  • Einfache Bedienung ohne manuelles Zählen

For the disinfection of cooling and lubricating emulsions as well as fuels, this PURION 2500 90W Pro can be used. When liquids with a high density or poor UV-C light permeability need to be disinfected, a low liquid film thickness between the reactor and the glass body is required. This allows the required power of 400 J/m² to be maintained. The ecological treatment of these liquids is sensible for various reasons: On one hand, it protects machines, as fine nozzles and injections are not clogged with algae or mold particles. On the other hand, the use of expensive chemicals can be avoided.

PURION 2500 Pro 90W can be maintained easily and without tools. It is suitable for the disinfection of 3,500 l/h of service water as well as 1,500 l/h of emulsions and fuels.

Weitere Produkte im Vergleich mit PURION 2500 90 W PRO Basic

Weitere Produkte im Vergleich mit PURION 2500 90 W PRO Basic
PURION 2500 90 W PRO Basic Dieses Produkt
Power consumption 90 W90 W
Water flow rate 3500 l/h service water, 1500 l/h emulsions3500 l/h service water, 1500 l/h emulsions
Dimensions 928 x 42 (L x W in mm)928 x 42 (L x W in mm)
Safety level without supervisionService life monitoring
Minimum flow rate is requiredis required
Recommended number of people 8 - 128 - 12
Pre-filtration optionaloptional
Spare parts included No
Preis 3.168,00 zł3.753,00 zł

Häufig gestellte Fragen zu PURION 2500 90 W PRO Basic

Hier findest du Antworten auf die häufigsten Fragen zu unserem Produkt.

A UV-C disinfection system is always the last link in a water treatment chain, as the path to the extraction point should be kept as short as possible. In particular, water filters offer ideal conditions for colonization by bacteria. The freshly disinfected water would therefore become contaminated again if it were to continue through the drinking water circuit after passing through the UV-C system. Pressure tanks should also always be installed before the UV-C systems.

Every UV-C lamp has a technically induced drop in UV-C performance. The manufacturer guarantees that the system still reaches 60% UV-C performance after 10,000 hours. The specified data for the systems always refer to this 60% performance. However, after 10,000 hours of operation, the performance drop continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C performance for an optimal disinfection result.

Lifetime monitoring is recommended for all users who do not leave the system permanently on. A lamp replacement every 10,000 hours is recommended because the manufacturer does not guarantee performance beyond that, i.e., the amount of UV-C radiation dose necessary for safe disinfection.

If no water is drawn during the operation of the lamps, the water inside the system heats up. In the 10W, 17W, and 36W systems, this effect is negligible as the water temperature does not rise above 40°C. However, if the water is heated more than 40°C, as is possible with the 48W and 90W variants, the lifespan of the lamp can be negatively affected. Therefore, it is recommended to ensure a constant water flow in these systems.

The UV system should be permanently switched on for various technical reasons:
1.) The UV system takes about 1 minute to reach full performance.
2.) Igniting the lamp requires about as much energy as operating it for two hours.
3.) Each on and off cycle reduces the lifespan.

The important factor here is not the average daily water consumption, but the maximum withdrawal amounts that can occur. Therefore, the correct drinking water system is determined by the existing extraction stations and the number of people in the house. A fully opened faucet has a capacity of 300 to 500 liters per hour. In case of doubt, the next stronger system should be used.

No, we recommend flow reactors because the maximum distance between the water to be disinfected and the UV-C lamp is precisely defined. A tank disinfection system can only ensure complete disinfection if it has a previously calculated circulation. Furthermore, flow reactors are significantly more efficient.

A UV-C sensor is used to measure the emitted UV-C performance directly at the lamp. This ensures much higher safety for the user, as a performance drop is directly signaled. This can be due to poor transmission or a natural performance drop of the lamp by reaching the recommended maximum operating time of 10,000 hours.

This should be clarified with the health department in case of doubt. For this purpose, the operating certificate for the systems is available in the download area of the respective product pages of this online shop. We are also happy to advise you personally on this topic. Alternatively, we also offer a UV system certified according to both DVGW and Ö-Norm with the PURION DVGW ZERT.

Hergestellt in Deutschland

Unsere Produkte stehen für höchste Qualität und werden mit Präzision in Deutschland gefertigt.

30 Tage kostenlose Rückgabe

Sie können Ihre Bestellung problemlos innerhalb von 30 Tagen kostenfrei zurücksenden.

Kostenfreie Kundenberatung

Unser erfahrenes Team steht Ihnen jederzeit kostenlos mit Rat und Tat zur Seite.

Offizieller Purion Händler

Vertrauen Sie auf die Garantie und Qualität eines offiziellen Purion-Händlers.

Ihr Berater

Ask a question

Do you have questions or would you like individual advice? Our expert is available on weekdays.

Opening hours: Mon–Fri 08:00–16:00

The fields marked * are required.