-
-
-
-
-
-
-
-
-
-
-
- PURION IBC DN150 17W SPL BS
- PURION IBC DN150 17W SPL BS OTC
- PURION IBC DN150 17W SPL BS 12 V/24 V
- PURION IBC DN150 17W SPL BS OTC 12 V/24 V
- PURION IBC DN150 36W SPL BS
- PURION IBC DN150 36W OTC SPL BS
- PURION IBC DN150 48W SPL BS
- PURION IBC DN150 48W OTC SPL BS
- PURION IBC DN150 90W SPL BS
- PURION IBC DN150 90W OTC SPL BS
-
- PURION IBC DN225 17W SPL BS
- PURION IBC DN225 17W SPL BS OTC
- PURION IBC DN225 17W SPL BS 12 V/24 V
- PURION IBC DN225 17W SPL BS OTC 12 V/24 V
- PURION IBC DN225 36W SPL BS
- PURION IBC DN225 36W OTC SPL BS
- PURION IBC DN225 48W SPL BS
- PURION IBC DN225 48W OTC SPL BS
- PURION IBC DN225 90W SPL BS
- PURION IBC DN225 90W OTC SPL BS
-
- PURION IBC Universal 17W SPL BS
- PURION IBC Universal 17W SPL BS OTC
- PURION IBC Universal 17W SPL BS 12V/24V
- PURION IBC Universal 17W SPL BS OTC 12V/24V
- PURION IBC Universal 36W SPL BS
- PURION IBC Universal 36W OTC SPL BS
- PURION IBC Universal 48W SPL BS
- PURION IBC Universal 48W OTC SPL BS
- PURION IBC Universal 90W SPL BS
- PURION IBC Universal 90W OTC SPL BS

We are happy to advise you!
Do you have questions or need individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
Description
The decision to set up a saltwater pool is usually driven by health aspects. Saltwater is soothing for the skin, gentle, and protects the body from dehydration. Precisely because of these positive effects, it is crucial that the pool is cleaned in a health-compatible manner. Cleaning with chlorine is absolutely not recommended here, as the positive properties of saltwater are almost completely negated by chlorine and other chemicals. The PURION 2001 P uses the UV-C disinfection process: Algae are specifically illuminated with UV-C light, causing the DNA connections to dissolve and the algae to die. This gentle method of water purification does not change the water in taste, smell, or composition. The PURION 2001 P can be applied to a saltwater pool with 30m³. For a health-promoting saltwater pool, there is no more compatible cleaning than UV-C – a cleaning that is environmentally friendly and economically attractive.
Thanks to a wide voltage ballast, this system is designed for a voltage range of 85-264V and can thus be used in many different countries. The system is equipped with a Euro plug and can also be used with an adapter (not included) for other plug types.
The UV-C lamp has a natural performance decline over its lifetime. We guarantee that the lamp will achieve the promised flow performance after 10,000 hours. After this time, the lamp must be replaced, and the lamp runtime counter and lifetime monitoring (OTC) signal the right time. The hours the lamp is on are counted, and the values are displayed via an LED indicator. Up to 9,000 hours, a green LED lights up, between 9,000 and 10,000 hours, a yellow LED indicates the pre-alarm, and after 10,000 hours, a red LED lights up. This ensures the right time for lamp replacement is not missed.
Due to the PVC reactor, this system is suitable for saltwater. Since the welds of stainless steel are attacked by salt, there is no alternative to PVC for the saltwater area.
To keep a pool permanently free of algae, the correct coordination between the pump and the UV-C system is necessary. It is essential that at least three times the pool volume flows through the UV-C system per day. The maximum flow rate of 8m³/h should not be exceeded, as this will result in the water not being properly disinfected. In certain cases, it is necessary to run the system longer: This is urgently required, for example, after heavy rainfall or if the water has been in the pool over the winter.
In an unfavorable starting situation with a lot of algae, it can be advantageous to use a biological flocculant to support the UV-C system.
In this Bundle, an additional replacement lamp, the appropriate mounting frame, and a service kit for intensive cleaning are included in addition to the system.
Available monitoring levels for this product
Our UV-C systems offer various surveillance levels that are tailored to every individual requirement.

With lifespan monitoring
- Automatic term measurement of the UV-C lamp
- LED displays for status and pre-alarms (green/yellow/red)
- Easy operation without manual counting
ab 3.929,00 zł
SelectedTechnical data
Here you will find all technical specifications.
Connection | Adhesive sleeve DN50 |
Reactor | PVC-U |
UVC Transmission | 90% T1 cm |
Plant type | PURION 2001 PVC-U |
Weight | 6 kg |
Poetry | FPM |
Water temperature | 8 °C to 40 °C |
Electrical connection | 110 - 240 V, 50 - 60 Hz |
Dosis | 300 J/m² |
Service life of spotlights | 10,000 h |
Performance | 48 W |
Protection | 10 A |
Flange distance | 360 mm |
Number of spotlights | 1 |
Dimensions (L x W in mm) | 670 x 100 |

We are happy to advise you!
Do you have questions or would like individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
+49 3641 327 9697 info@uvconcept.comDownloads
Technical documents for download
Scope of delivery
What is included in the delivery
- UV lamp (48 W)
- Replacement lamp (48 W)
- Service kit
- Suitable mounting brackets
- User manual
Frequently asked questions
Here you will find answers to the most frequently asked questions about our product.
The pool systems from the company PURION are not exposed to overheating problems if the UVC system is turned on but no water flow occurs.
No. We recommend always operating the UV system in combination with the pump, which utilizes the full flow for disinfection. Since the system has a relatively large diameter, there is no failure if the pump is defective and there is no water flow with the UV lamp turned on.
For optimal effect, we recommend circulating the entire pool content at least three times daily. However, the system should be in operation for at least 8 hours daily to ensure sufficient ventilation and filtration. The circulation rate depends on the performance of the pump and sand filter used. The net performance of the pump can be reduced by the lengths and heights of the pipes to be overcome. Also interesting: In our compact systems, the pump, sand filter, and UVC system are ideally matched and pre-assembled.
There is a simple calculation for this: the pool content should flow through the UV-C system at least three times a day to kill a large portion of the algae through proper mixing. If algae growth is increased, e.g., during phases of extreme sunlight or after heavy rainfall or a thunderstorm, we recommend temporarily setting the circulation rate to four times. Regardless of the circulation rate, we recommend having the system in operation for at least 8 hours daily to allow sufficient ventilation and filtration.
By considering all three basic recommendations for using a UV-C system in the pool area, the pool can be operated completely without chlorine. The occasional use of a biological flocculant may be advisable. However, our high-quality UV-C lamps allow a combination of chlorine and UV-C, as no ozone is produced, which would react with chlorine.
The high-quality UV-C lamps from the brand PURION are durable and very powerful. They produce a very high UV-C content. The lamps we use in the pool area are also used in other systems for drinking water treatment. The UV lamps used do not emit radiation below 250nm, which excludes the formation of toxic ozone. Thus, the systems from PURION can be used in combination with other treatment methods that use chlorine, for example.
No, from our perspective, ozone should not be used in the pool area under any circumstances. Ozone is highly toxic. Excess ozone must be laboriously destroyed again, and it is often unclear how much ozone is left. Furthermore, ozone reacts with chlorine, significantly reducing the effectiveness of both methods. Cheaply produced UV lamps often emit radiation below 250nm, which can form ozone. This is excluded in the systems from PURION.
Each UV-C lamp exhibits a technically induced decline in UV-C output. The manufacturer guarantees that the system will still achieve 60% UV-C output after 10,000 hours. The specified data for the systems always refer to this 60% output. However, after 10,000 hours of operation, the decline in output continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C output for optimal disinfection results.
A lifespan monitoring is recommended for all users who do not keep the system permanently switched on. It is recommended to replace the lamp every 10,000 hours, as the manufacturer does not guarantee the performance, i.e., the amount of UV-C radiation dose necessary for safe disinfection, beyond that.
Suitable accessories for PURION 2001 PVC-U OTC Bundle






Related posts about the product

UV system for pools: Simple and effective
Everything important about shipping & purchase
Do you Brauchen Sie Hilfe? We are here for you!