Skip to content

Official Purion Dealer

Delivery throughout Europe

The “PURION DVGW-certified active ESM” from PURION GmbH is an industrial water filtration and treatment system featuring a control panel, blue filter housings, stainless steel components, pressure gauges, as well as a variety of pipes and valves mounted on a sturdy metal frame – designed for drinking water treatment and equipped with a DVGW-certified UVC disinfection reactor that ensures reliable disinfection.

PURION DVGW Zert.

Regular price 7.421,67€
Sale price Regular price

Available monitoring levels for this product

Our UV-C systems offer various monitoring levels tailored to every individual requirement.

Bestseller
With sensor monitoring

With sensor monitoring

  • Continuous monitoring of UV-C performance
  • LED indicators for performance intensity (green/yellow/red)
  • Immediate detection of contamination or performance drop
  • Optimal control without additional effort

The PURION DVGW Zert active ESM combines all essential components of professional drinking water treatment in a pre-assembled, ready-to-connect system. Mounted on a sturdy aluminum profile frame, it combines a powerful Grundfos domestic waterworks JP 4-54 PT, a double Big Blue pre-filter with a 50 µm suspended solids filter and activated carbon filter, as well as a DVGW-certified PURION 106 W UVC disinfection reactor. With an output of 400 J/m² at 3.4 m³/h, the system is perfectly suited for single-family and multi-family homes as well as commercial units. It is certified and approved according to both DVGW DIN 19294-1 and ÖNorm M 5873-1:2020-01-01, thereby ensuring that the water to be treated is disinfected both reliably and in legal compliance.

For maximum operational safety, the system is also equipped with a 40 µm backwashable pre-filter, pressure reducer, shut-off valves, an automatically closing solenoid valve, as well as a sampling tap directly behind the UVC unit. This allows water samples to be conveniently taken at any time and the water quality to be reliably monitored.

The integrated DVGW-certified 106 W UVC unit meets the highest requirements for drinking water disinfection and features permanent UVC sensor monitoring (OPD). The integrated sensor continuously measures the actual UVC output delivered and thus ensures seamless monitoring of the disinfection effect. If the UVC intensity falls below the permissible limit value, the de-energized solenoid valve automatically shuts off the water flow. This reliably prevents insufficiently disinfected water from entering the drinking water network. The result is permanently safe, standards-compliant, and fully automatically monitored water disinfection at the highest level.

Thanks to the special lamp design, this system is also approved for temperature ranges up to 90°C and can therefore be used for legionella prevention. 

The usual installation rules for UVC systems must be observed: as close as possible to the points of use, and as the final stage in the water treatment chain.

More products compared with PURION DVGW Zert.

More products compared with PURION DVGW Zert.
PURION DVGW Zert. This product
Power consumption 106 W106 W106 W
Water flow rate 3,400 l/h drinking water (DVGW) / 5,000 l/h3,400 l/h drinking water3,400 l/h drinking water
Dimensions 980 x 530 x 1300 (L x W x H in mm)1020 x 510 x 1150 (L x W x H in mm)928 x 85 (L x W in mm)
Safety level Sensor monitoringSensor monitoringSensor monitoring
Minimum flow rate is requiredis requiredis required
Recommended number of people 1 - 101 - 101 - 10
Pre-filtration includingoptionaloptional
Spare parts included NoNoNo
Price 7.421,67€4.981,34€2.979,00€

Frequently asked questions about PURION DVGW Zert.

Here you will find answers to the most frequently asked questions about our product.

A UV-C disinfection system is always the last link in a water treatment chain, as the path to the extraction point should be kept as short as possible. In particular, water filters offer ideal conditions for colonization by bacteria. The freshly disinfected water would therefore become contaminated again if it were to continue through the drinking water circuit after passing through the UV-C system. Pressure tanks should also always be installed before the UV-C systems.

Every UV-C lamp has a technically induced drop in UV-C performance. The manufacturer guarantees that the system still reaches 60% UV-C performance after 10,000 hours. The specified data for the systems always refer to this 60% performance. However, after 10,000 hours of operation, the performance drop continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C performance for an optimal disinfection result.

Lifetime monitoring is recommended for all users who do not leave the system permanently on. A lamp replacement every 10,000 hours is recommended because the manufacturer does not guarantee performance beyond that, i.e., the amount of UV-C radiation dose necessary for safe disinfection.

If no water is drawn during the operation of the lamps, the water inside the system heats up. In the 10W, 17W, and 36W systems, this effect is negligible as the water temperature does not rise above 40°C. However, if the water is heated more than 40°C, as is possible with the 48W and 90W variants, the lifespan of the lamp can be negatively affected. Therefore, it is recommended to ensure a constant water flow in these systems.

The UV system should be permanently switched on for various technical reasons:
1.) The UV system takes about 1 minute to reach full performance.
2.) Igniting the lamp requires about as much energy as operating it for two hours.
3.) Each on and off cycle reduces the lifespan.

The important factor here is not the average daily water consumption, but the maximum withdrawal amounts that can occur. Therefore, the correct drinking water system is determined by the existing extraction stations and the number of people in the house. A fully opened faucet has a capacity of 300 to 500 liters per hour. In case of doubt, the next stronger system should be used.

No, we recommend flow reactors because the maximum distance between the water to be disinfected and the UV-C lamp is precisely defined. A tank disinfection system can only ensure complete disinfection if it has a previously calculated circulation. Furthermore, flow reactors are significantly more efficient.

A UV-C sensor is used to measure the emitted UV-C performance directly at the lamp. This ensures much higher safety for the user, as a performance drop is directly signaled. This can be due to poor transmission or a natural performance drop of the lamp by reaching the recommended maximum operating time of 10,000 hours.

This should be clarified with the health department in case of doubt. For this purpose, the operating certificate for the systems is available in the download area of the respective product pages of this online shop. We are also happy to advise you personally on this topic. Alternatively, we also offer a UV system certified according to both DVGW and Ö-Norm with the PURION DVGW ZERT.

Made in Germany

Our products stand for the highest quality and are manufactured with precision in Germany.

30 days free returns

You can return your order free of charge within 30 days without any hassle.

Free customer support

Our experienced team is always available to provide you with free advice and assistance.

Official Purion dealer

Rely on the warranty and quality of an official Purion dealer.

Ihr Berater

Ask a question

Do you have questions or would you like individual advice? Our expert is available on weekdays.

Opening hours: Mon–Fri 08:00–16:00

The fields marked * are required.