-
-
-
-
-
-
-
-
-
-
-
- PURION IBC DN150 17W SPL BS
- PURION IBC DN150 17W SPL BS OTC
- PURION IBC DN150 17W SPL BS 12 V/24 V
- PURION IBC DN150 17W SPL BS OTC 12 V/24 V
- PURION IBC DN150 36W SPL BS
- PURION IBC DN150 36W OTC SPL BS
- PURION IBC DN150 48W SPL BS
- PURION IBC DN150 48W OTC SPL BS
- PURION IBC DN150 90W SPL BS
- PURION IBC DN150 90W OTC SPL BS
-
- PURION IBC DN225 17W SPL BS
- PURION IBC DN225 17W SPL BS OTC
- PURION IBC DN225 17W SPL BS 12 V/24 V
- PURION IBC DN225 17W SPL BS OTC 12 V/24 V
- PURION IBC DN225 36W SPL BS
- PURION IBC DN225 36W OTC SPL BS
- PURION IBC DN225 48W SPL BS
- PURION IBC DN225 48W OTC SPL BS
- PURION IBC DN225 90W SPL BS
- PURION IBC DN225 90W OTC SPL BS
-
- PURION IBC Universal 17W SPL BS
- PURION IBC Universal 17W SPL BS OTC
- PURION IBC Universal 17W SPL BS 12V/24V
- PURION IBC Universal 17W SPL BS OTC 12V/24V
- PURION IBC Universal 36W SPL BS
- PURION IBC Universal 36W OTC SPL BS
- PURION IBC Universal 48W SPL BS
- PURION IBC Universal 48W OTC SPL BS
- PURION IBC Universal 90W SPL BS
- PURION IBC Universal 90W OTC SPL BS

We are happy to advise you!
Do you have questions or need individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
Description
The guests of a hotel complex want to find a pool in perfect condition. To achieve this, a large number of chemicals such as chlorine, flocculants, pH boosters and pH reducers are often added to the pool water. An alternative method to this chemical mace is cleaning using the physical process of UV-C disinfection. In this process, the DNA of algae and bacteria is specifically dissolved so that they die. With the help of the PURION 2501 Dual, which is based on the concept of PURION 2501, this process can be used perfectly for pools up to 100m³. Pool users no longer swim in chemicals, but in naturally clear and clean water. Unpleasant effects such as the famous red eyes or itchy skin can thus be avoided. And the guests of the hotel complex are guaranteed to be happy to return. The PURION 2501 Dual is not only worthwhile for the guests, but also for the owner. Chemicals are very expensive in the long term, but the running costs for a UV-C disinfection system are manageable. For perfect bathing fun, there is therefore nothing better from an economic and ecological point of view than cleaning the pool with a UV-C disinfection system PURION 2501 Dual.
Thanks to a wide-voltage ballast, this system is designed for a voltage range of 85-264V and can therefore be used in many different countries. The system is equipped with a Euro plug and can also be used for other plug types with an adapter (not included).
The UV-C lamp has a natural power drop over the course of its service life. We guarantee that after 10,000 hours the lamp will have reached exactly the promised flow rate. After this time, the lamp must be replaced; the lamp life meter and the service life monitor (OTC) signal the right time. The hours in which the lamp is switched on are counted and the values are shown on an LED display. Up to 9,000 hours a green LED lights up, between 9,000 and 10,000 hours the pre-alarm is indicated by a yellow LED and after 10,000 hours a red LED lights up. This ensures that the right time to change the bulb is not missed.
To keep a pool permanently free of algae, the pump and UV-C system must be correctly coordinated. At least three times the pool volume should flow through the UV-C system during the day. The maximum flow rate of 20m³/h should not be exceeded, as this would result in the water no longer being disinfected correctly. In certain cases, it is necessary to run the system for longer: This is urgently required after heavy rainfall, for example, or if the water has been standing in the pool over the winter.
In addition to the system, this bundle also includes another replacement lamp, the appropriate mounting frame and a service kit for intensive cleaning.
Available monitoring levels for this product
Our UV-C systems offer various surveillance levels that are tailored to every individual requirement.

With lifespan monitoring
- Automatic term measurement of the UV-C lamp
- LED displays for status and pre-alarms (green/yellow/red)
- Easy operation without manual counting
ab 2.411,82€
SelectedTechnical data
Here you will find all technical specifications.
Connection | R 1 1/2" |
Reactor | Stainless steel 1.4571 |
UVC Transmission | 90% T1 cm |
Plant type | PURION 2501 DUAL |
Weight | 11 kg |
Poetry | FPM |
Water temperature | 2 °C to 40 °C |
Electrical connection | 110 - 240 V, 50 - 60 Hz |
Dosis | 400 J/m² |
Service life of spotlights | 10,000 h |
Performance | 90 W (2x) |
Protection | 10 A |
Flange distance | 810 mm |
Maximum operating pressure | 10 bar |
Number of spotlights | 2 |
Dimensions (L x W in mm) | 928 x 85 (2x) |

We are happy to advise you!
Do you have questions or would like individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
+49 3641 327 9697 info@uvconcept.comDownloads
Technical documents for download
Scope of delivery
What is included in the delivery
- 2x UV lamp (90 W)
- 2x replacement lamp (90 W)
- Service kit
- Suitable mounting brackets
- Operating instructions
Frequently asked questions
Here you will find answers to the most frequently asked questions about our product.
The pool systems from the company PURION are not exposed to overheating problems if the UVC system is turned on but no water flow occurs.
No. We recommend always operating the UV system in combination with the pump, which utilizes the full flow for disinfection. Since the system has a relatively large diameter, there is no failure if the pump is defective and there is no water flow with the UV lamp turned on.
For optimal effect, we recommend circulating the entire pool content at least three times daily. However, the system should be in operation for at least 8 hours daily to ensure sufficient ventilation and filtration. The circulation rate depends on the performance of the pump and sand filter used. The net performance of the pump can be reduced by the lengths and heights of the pipes to be overcome. Also interesting: In our compact systems, the pump, sand filter, and UVC system are ideally matched and pre-assembled.
There is a simple calculation for this: the pool content should flow through the UV-C system at least three times a day to kill a large portion of the algae through proper mixing. If algae growth is increased, e.g., during phases of extreme sunlight or after heavy rainfall or a thunderstorm, we recommend temporarily setting the circulation rate to four times. Regardless of the circulation rate, we recommend having the system in operation for at least 8 hours daily to allow sufficient ventilation and filtration.
By considering all three basic recommendations for using a UV-C system in the pool area, the pool can be operated completely without chlorine. The occasional use of a biological flocculant may be advisable. However, our high-quality UV-C lamps allow a combination of chlorine and UV-C, as no ozone is produced, which would react with chlorine.
The high-quality UV-C lamps from the brand PURION are durable and very powerful. They produce a very high UV-C content. The lamps we use in the pool area are also used in other systems for drinking water treatment. The UV lamps used do not emit radiation below 250nm, which excludes the formation of toxic ozone. Thus, the systems from PURION can be used in combination with other treatment methods that use chlorine, for example.
No, from our perspective, ozone should not be used in the pool area under any circumstances. Ozone is highly toxic. Excess ozone must be laboriously destroyed again, and it is often unclear how much ozone is left. Furthermore, ozone reacts with chlorine, significantly reducing the effectiveness of both methods. Cheaply produced UV lamps often emit radiation below 250nm, which can form ozone. This is excluded in the systems from PURION.
Each UV-C lamp exhibits a technically induced decline in UV-C output. The manufacturer guarantees that the system will still achieve 60% UV-C output after 10,000 hours. The specified data for the systems always refer to this 60% output. However, after 10,000 hours of operation, the decline in output continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C output for optimal disinfection results.
A lifespan monitoring is recommended for all users who do not keep the system permanently switched on. It is recommended to replace the lamp every 10,000 hours, as the manufacturer does not guarantee the performance, i.e., the amount of UV-C radiation dose necessary for safe disinfection, beyond that.
Suitable accessories for PURION 2501 DUAL OTC Bundle







Related posts about the product

UV system for pools: Simple and effective
Zuletzt angesehen
Everything important about shipping & purchase
Do you Brauchen Sie Hilfe? We are here for you!