4,89 Very good 172 Bewertungen

PURION IBC DN150 36W OTC SPL BS


icon
Monitoring level: with lifespan monitoring Compare monitoring levels

Price:
Special price752,63€

incl. VAT Shipping costs will be calculated at checkout.

Power supply: 110 - 240 V AC
In stock - with you in 2-4 business days
PayPal Mastercard Visa American Express Klarna Apple Pay
delivery-truck.png__PID:205694ad-0c81-4c4f-a9a5-a1b05184f262
Faster and safe shipping

box.png__PID:9263acad-f9bf-4141-88c6-71beb2205694
30 days free returns

Purion Logo neue.png__PID:da4b9263-acad-49bf-a141-88c671beb220
Official Purion dealer

Description

The PURION IBC Tank Set 36W is used for clear water. It protects the tank from contamination, such as the formation of a biofilm. In particular, the air flowing in when water is drawn from the tank is disinfected, which can very quickly cause contamination. This set is particularly useful in combination with flow systems from PURION, as it protects the tank from excessive contamination and treats the water to drinking water quality when drawn.

Features of the PURION IBC Tank Set 36W:

 

Plus (OTC/Lifetime Monitoring)

Full control of the lamp with the help of integrated lifetime monitoring, which signals when the guaranteed lifetime of 10,000 operating hours has expired and the lamp needs to be replaced.

Shatter Protection

The protective glass is additionally coated with a Teflon layer so that in the event of an accident, such as cleaning, no glass shards are created, effectively protecting the tank from contamination and people from injuries.

Safety System

The immersion lamp is additionally secured with 3 metal rods, making it rigid and allowing it to be freely suspended in the tank.

Immersion Length

The immersion length of this system is 920 mm, making it suitable for clear water of all tank sizes.

Available monitoring levels for this product

Our UV-C systems offer various surveillance levels that are tailored to every individual requirement.

Ohne Überwachungsstufe

without monitoring level

  • Manuelle Inspektion erforderlich
  • Unabhängig von Technik nutzbar

ab 574,13€

Zum Produkt
Mit Lebensdauer-überwachung

With lifespan monitoring

  • Automatic term measurement of the UV-C lamp
  • LED displays for status and pre-alarms (green/yellow/red)
  • Easy operation without manual counting

ab 752,63€

Selected

Technical data

Here you will find all technical specifications.

Plant type PURION IBC UV Set 36 W OTC DN150
Weight 2.5 kg
Electrical connection 110-240 V/24 V 50/60 Hz
Service life of spotlights 10,000 h
Performance 36 W
Protection 10 A
Throughput depending on the medium and geometric structure of the container, a calculation is required
Maximum operating pressure 10 bar
Number of spotlights 1
Fastening IBC tank lid: DN150
Diameter quartz tube Ø 23 mm
Support

We are happy to advise you!

Do you have questions or would like individual advice? Our expert is available on weekdays.

Opening hours: Mon–Fri 08:00–16:00

+49 3641 327 9697 info@uvconcept.com
Submit a product inquiry

Downloads

Technical documents for download

Scope of delivery

What is included in the delivery

- Immersion tube system 23/920 Set BS Spl
(Safety bracket & shatter protection)
- Control box with ballast 110-240 VAC or 24 V DC,
lamp cable ~ 3m, UV lamp 36 W
- IBC tank lid DN150 with 2 x 1" external thread
- 2 x threaded cap internal thread with O-ring 1" IG

Frequently asked questions

Here you will find answers to the most frequently asked questions about our product.

A UV-C disinfection system is always the last link in a water treatment chain, as the path to the point of use should be kept as short as possible. In particular, water filters provide ideal conditions for colonization by bacteria. The freshly disinfected water would therefore become contaminated again if it were to continue through the drinking water circuit after passing through the UV-C system. Pressure tanks should also always be installed before the UV-C systems.

Lifetime monitoring is recommended for all users who do not leave the system permanently on. A lamp change every 10,000 hours is recommended, as the manufacturer does not guarantee performance beyond that, meaning the amount of UV-C radiation dose necessary for safe disinfection.

The UV system should be permanently switched on for various technical reasons:
1.) The UV system takes about 1 minute to reach full power.
2.) When igniting the lamp, approximately as much energy is needed as for operation over two hours.
3.) Each on and off cycle shortens the lifespan.

The correct sizing of the systems is not based on the maximum daily consumption but on the expected maximum peak rate and is therefore dependent on the pump's performance.

It should be noted that no power supplies with pulsed voltage should be used, as this can cause irreparable damage to the system.

Yes, that is possible. However, it is always recommended to use a battery to ignite the lamp. Additionally, a solar controller should always be used.

No, we recommend flow reactors, as this precisely defines the maximum distance between the water to be disinfected and the UV-C lamp. A tank disinfection system can only ensure complete disinfection if it has a previously calculated circulation. Furthermore, flow reactors are significantly more efficient.

Zuletzt angesehen

Die PURION GmbH bietet PURION 2001 OPD Extra UV-C-Desinfektion für Pools an.
PURION 2001 OPD Extra
icon
Sensor monitoring

Special pricefrom 1.069,93€
Choose your options

Everything important about shipping & purchase

Do you Brauchen Sie Hilfe? We are here for you!