- PURION IBC DN150 17W SPL BS
- PURION IBC DN150 17W SPL BS OTC
- PURION IBC DN150 17W SPL BS 12 V/24 V
- PURION IBC DN150 17W SPL BS OTC 12 V/24 V
- PURION IBC DN150 36W SPL BS
- PURION IBC DN150 36W OTC SPL BS
- PURION IBC DN150 48W SPL BS
- PURION IBC DN150 48W OTC SPL BS
- PURION IBC DN150 90W SPL BS
- PURION IBC DN150 90W OTC SPL BS
-
- PURION IBC DN225 17W SPL BS
- PURION IBC DN225 17W SPL BS OTC
- PURION IBC DN225 17W SPL BS 12 V/24 V
- PURION IBC DN225 17W SPL BS OTC 12 V/24 V
- PURION IBC DN225 36W SPL BS
- PURION IBC DN225 36W OTC SPL BS
- PURION IBC DN225 48W SPL BS
- PURION IBC DN225 48W OTC SPL BS
- PURION IBC DN225 90W SPL BS
- PURION IBC DN225 90W OTC SPL BS
-
- PURION IBC Universal 17W SPL BS
- PURION IBC Universal 17W SPL BS OTC
- PURION IBC Universal 17W SPL BS 12V/24V
- PURION IBC Universal 17W SPL BS OTC 12V/24V
- PURION IBC Universal 36W SPL BS
- PURION IBC Universal 36W OTC SPL BS
- PURION IBC Universal 48W SPL BS
- PURION IBC Universal 48W OTC SPL BS
- PURION IBC Universal 90W SPL BS
- PURION IBC Universal 90W OTC SPL BS

We are happy to advise you!
Do you have questions or need individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
Description
The AIRPURION series is suitable for the disinfection of air and surfaces, with its emitters capable of being operated directly or indirectly. The back is coated with polished aluminum, allowing for optimal performance utilization. By breaking down the DNA of microorganisms, the UV-C disinfection system provides optimal disinfection of bacteria, germs, and viruses. The efficient PURION UV-C lamps operate with high power output and have a very long lifespan of 10,000 hours. This system can only be operated in rooms where there are no people or animals present. Please read the warnings regarding this.
The AIRPURION-Dry systems are intended for use in dry rooms. In this case, the UV-C lamps are not in an immersion tube system, which is reflected in a more favorable price.
Available monitoring levels for this product
Our UV-C systems offer various monitoring levels tailored to each individual requirement.

Without monitoring level
- Manual inspection required
- Usable independently of technology
ab 487,26€
SelectedTechnical data
Here you will find all technical specifications.
Plant type | AIRPURION 48 W dry |
Weight | 2 kg |
Electrical connection | 110 - 240 V, 50 - 60 Hz |
Service life of spotlights | 10,000 h |
Performance | 48 W |
Protection | 10 A |
Number of spotlights | 1 |
Irradiation width | 380 mm |
Disinfection level 88% | approx. 35 m³ room volume |
Disinfection level 80% | approx. 70 m³ room volume |
Dimensions (L x W x H in mm) | 700 x 67 x 100 |

We are happy to advise you!
Do you have questions or would like individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
+49 3641 327 9697 info@uvconcept.comDownloads
Technical documents for download
Scope of delivery
What is included in the delivery
- UV lamp (48 W)
- User manual
Frequently asked questions
Here you will find answers to the most frequently asked questions about our product.
Depending on the device configuration, a dose between 65 and 120J/m² is achieved. This enables a disinfection performance of 99.99% for all our systems. Based on our experience, this can achieve disinfection of the entire room air between 80% and 88%. We recommend 80% for storage, sports, and generally larger halls. We recommend 88% for rooms with public traffic, such as offices, classrooms, conference or practice rooms, etc. Please note any special requirements of the legislator. If you have any questions, you can contact our customer service.
The systems are designed and approved according to the latest regulations. If necessary, our customer service can answer questions on the subject and provide appropriate evidence.
Our high-quality UV-C lamps are designed so that no wavelengths below 250nm are emitted. As a result, no ozone is produced, and the AIRPURION active systems can be used without problems in rooms with public traffic, offices, schools, conference rooms, etc.
Due to the constant air exchange, there is no overheating.
We generally recommend ceiling installation, as this directs the airflow upwards. With floor-standing units, untreated air may be directed horizontally through the room at a lower height. This can concentrate contamination in limited areas, which in the worst case can even increase the risk of infection.
The systems should be placed in the room so that they work with the room's convection. The room air rises where it is heated. This way, it distributes itself, for example, from a radiator, throughout the room. Ideally, this creates an even distribution in the room. The UV-C systems should not work against the convection. Please note that room dividers, tall cabinets, or similar can also influence the air circulation in the room. We would be happy to provide you with a recommendation on where the systems should ideally be placed in the room. For this, we need floor plans showing radiators, windows, and doors. Please feel free to contact our customer service.
Every UV-C lamp has a technically induced decrease in UV-C performance. The manufacturer guarantees that the system will still achieve 60% UV-C performance after 10,000 hours. The specified data for the systems always refer to this 60% performance. After 10,000 hours of operation, the performance decrease continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C performance for optimal disinfection results.
Suitable accessories for AIRPURION 48 W dry


Related posts about the product
Zuletzt angesehen
Everything important about shipping & purchase
Do you Brauchen Sie Hilfe? We are here for you!