4,89 Sehr gut 172 Bewertungen

PURION 2500 36 W 110 - 240 V AC Basic


icon
Überwachungsstufe: ohne Überwachungsstufe Überwachungsstufen vergleichen

✓ Reliable quality

✓ Access to spare parts

✓ More than 15 years of experience

✓ Food-grade stainless steel

Price:
Special price533,45€

incl. VAT Shipping costs will be calculated at checkout.

Cable extension: Standard 1.5 m
Auf Lager - in 2-4 Werktagen bei Ihnen
PayPal Mastercard Visa American Express Klarna Apple Pay
delivery-truck.png__PID:205694ad-0c81-4c4f-a9a5-a1b05184f262
Schneller & sicherer Versand

box.png__PID:9263acad-f9bf-4141-88c6-71beb2205694
30 Tage kostenlose Rückgabe

Purion Logo neue.png__PID:da4b9263-acad-49bf-a141-88c671beb220
Offizieller Purion Händler 

Description

Verfügbare Überwachungsstufen für dieses Produkt

Unsere UV-C-Anlagen bieten verschiedene Überwachungsstufen, die auf jede individuelle Anforderung abgestimmt sind.

Ohne Überwachungsstufe

Ohne Überwachungsstufe

  • Manuelle Inspektion erforderlich
  • Unabhängig von Technik nutzbar

ab 533,45€

Ausgewählt
Mit Lebensdauer-überwachung

Mit Lebensdauer-überwachung

  • Automatische Laufzeitmessung der UV-C-Lampe
  • LED-Anzeigen für Status und Voralarme (Grün/Gelb/Rot)
  • Einfache Bedienung ohne manuelles Zählen

ab 654,46€

Zum Produkt
Bestseller
With sensor monitoring

With sensor monitoring

  • Permanent monitoring of UV-C performance
  • LED indicators for performance intensity (Green/Yellow/Red)
  • Immediate detection of contamination or performance drop
  • Optimal control without additional effort

ab 946,90€

Zum Produkt
With solenoid valve

With solenoid valve

  • Permanent monitoring of UV-C performance
  • LED indicators for intensity (Green/Yellow/Red)
  • Automatic shutdown in case of performance drop
  • Powerless solenoid valve protects even in case of power failure
  • Maximum efficiency and user-friendliness

ab 1.612,44€

Zum Produkt

Technical data

Here you will find all technical specifications.

Anschluss R 1"
Reaktor Stainless steel 1.4571
UVC-Transmission 90% T1 cm
Anlagentyp PURION 2500 36W
Gewicht 3.4 kg
Dichtung FPM
Wassertemperatur 2 ºC to 40 ºC
Elektrischer Anschluss 110 - 240 V, 50 - 60 Hz
Dosis 400 J/m²
Strahlernutzungsdauer 10,000 h
Leistung 36 W
Absicherung 10 A
Durchsatz 2,500 l/h drinking water
Flanschabstand 850 mm
Maximaler Betriebsdruck 10 bar
Anzahl der Strahler 1
Dimensionen (L x B in mm) 928 x 42
Support

We are happy to advise you!

Do you have questions or would like individual advice? Our expert is available on weekdays.

Öffnungszeiten: Mon–Fri 08:00–16:00

+49 3641 327 9697 info@uvconcept.com
Submit a product inquiry

Downloads

Technical documents for download

Scope of delivery

What is included in the delivery

- UV disinfection system
- UV lamp (36 W)
- User manual

Frequently asked questions

Here you will find answers to the most frequently asked questions about our product.

A UV-C disinfection system is always the last link in a water treatment chain, as the path to the extraction point should be kept as short as possible. In particular, water filters offer ideal conditions for colonization by bacteria. The freshly disinfected water would therefore become contaminated again if it were to continue through the drinking water circuit after passing through the UV-C system. Pressure tanks should also always be installed before the UV-C systems.

Every UV-C lamp has a technically induced drop in UV-C performance. The manufacturer guarantees that the system still reaches 60% UV-C performance after 10,000 hours. The specified data for the systems always refer to this 60% performance. However, after 10,000 hours of operation, the performance drop continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C performance for an optimal disinfection result.

Lifetime monitoring is recommended for all users who do not leave the system permanently on. A lamp replacement every 10,000 hours is recommended because the manufacturer does not guarantee performance beyond that, i.e., the amount of UV-C radiation dose necessary for safe disinfection.

If no water is drawn during the operation of the lamps, the water inside the system heats up. In the 10W, 17W, and 36W systems, this effect is negligible as the water temperature does not rise above 40°C. However, if the water is heated more than 40°C, as is possible with the 48W and 90W variants, the lifespan of the lamp can be negatively affected. Therefore, it is recommended to ensure a constant water flow in these systems.

The UV system should be permanently switched on for various technical reasons:
1.) The UV system takes about 1 minute to reach full performance.
2.) Igniting the lamp requires about as much energy as operating it for two hours.
3.) Each on and off cycle reduces the lifespan.

The important factor here is not the average daily water consumption, but the maximum withdrawal amounts that can occur. Therefore, the correct drinking water system is determined by the existing extraction stations and the number of people in the house. A fully opened faucet has a capacity of 300 to 500 liters per hour. In case of doubt, the next stronger system should be used.

No, we recommend flow reactors because the maximum distance between the water to be disinfected and the UV-C lamp is precisely defined. A tank disinfection system can only ensure complete disinfection if it has a previously calculated circulation. Furthermore, flow reactors are significantly more efficient.

A UV-C sensor is used to measure the emitted UV-C performance directly at the lamp. This ensures much higher safety for the user, as a performance drop is directly signaled. This can be due to poor transmission or a natural performance drop of the lamp by reaching the recommended maximum operating time of 10,000 hours.

This should be clarified with the health department in case of doubt. For this purpose, the operating certificate for the systems is available in the download area of the respective product pages of this online shop. We are also happy to advise you personally on this topic. Alternatively, we also offer a UV system certified according to both DVGW and Ö-Norm with the PURION DVGW ZERT.

For safe disinfection, we use a UV-C dose of 400 J/m². This performance is sufficient to achieve a disinfection rate of 99.99% while maintaining the specified flow rate and transmission. Thus, water from a tank or containers can be treated precisely.

Related posts about the product

Ratgeber zur UVC-Desinfektion: Alles, was Sie wissen müssen - Trinkwasser

Guide to UVC Disinfection: Everything You Need to Know - Drinking Water

Experience the benefits of UVC disinfection: chemical-free, effective, and sustainable – for germ-free and safe drinking water in every household.

Zuletzt angesehen

Alles Wichtige zu Versand & Kauf

Benötigst du Hilfe? Wir sind für dich da!