- PURION IBC DN150 17W SPL BS
- PURION IBC DN150 17W SPL BS OTC
- PURION IBC DN150 17W SPL BS 12 V/24 V
- PURION IBC DN150 17W SPL BS OTC 12 V/24 V
- PURION IBC DN150 36W SPL BS
- PURION IBC DN150 36W OTC SPL BS
- PURION IBC DN150 48W SPL BS
- PURION IBC DN150 48W OTC SPL BS
- PURION IBC DN150 90W SPL BS
- PURION IBC DN150 90W OTC SPL BS
-
- PURION IBC DN225 17W SPL BS
- PURION IBC DN225 17W SPL BS OTC
- PURION IBC DN225 17W SPL BS 12 V/24 V
- PURION IBC DN225 17W SPL BS OTC 12 V/24 V
- PURION IBC DN225 36W SPL BS
- PURION IBC DN225 36W OTC SPL BS
- PURION IBC DN225 48W SPL BS
- PURION IBC DN225 48W OTC SPL BS
- PURION IBC DN225 90W SPL BS
- PURION IBC DN225 90W OTC SPL BS
-
- PURION IBC Universal 17W SPL BS
- PURION IBC Universal 17W SPL BS OTC
- PURION IBC Universal 17W SPL BS 12V/24V
- PURION IBC Universal 17W SPL BS OTC 12V/24V
- PURION IBC Universal 36W SPL BS
- PURION IBC Universal 36W OTC SPL BS
- PURION IBC Universal 48W SPL BS
- PURION IBC Universal 48W OTC SPL BS
- PURION IBC Universal 90W SPL BS
- PURION IBC Universal 90W OTC SPL BS

We are happy to advise you!
Do you have questions or need individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
Description
Liquids such as cooling and lubricating emulsions as well as fuels can easily spoil and go bad. This can lead to machines being damaged, for example, by fine nozzles becoming clogged with mold or algae particles. Harmful chemicals are often used to prevent this, which is not only harmful to the environment but also associated with high costs. These high-density liquids can be reliably disinfected with the PURION 500 system using UV-C radiation. The liquid film thickness is only 2mm, so the UV performance does not suffer even with low UV transmission. Service water can be disinfected at 300 l/h, emulsions at 200 l/h. The PURION 500 can be maintained without tools, which applies to both cleaning and the installation of spare parts.
In this configuration, the Pro system has no monitoring, it only indicates when the lamp has a failure. It should be noted that the lamp needs to be replaced after 10,000 hours. Within these 10,000 hours, the lamp always has a performance of at least 60%. With this performance, the promised disinfection performance can be maintained.
Available monitoring levels for this product
Our UV-C systems offer various surveillance levels that are tailored to every individual requirement.

without monitoring level
- Manuelle Inspektion erforderlich
- Unabhängig von Technik nutzbar
ab 574,69€
Selected
With lifespan monitoring
- Automatic term measurement of the UV-C lamp
- LED displays for status and pre-alarms (green/yellow/red)
- Easy operation without manual counting
ab 713,30€
Zum ProduktTechnical data
Here you will find all technical specifications.
Connection | R 1/2" |
Reactor | Stainless steel 1.4571 |
UVC Transmission | 20% T1 cm |
Plant type | PURION 500 Pro |
Weight | 2 kg |
Poetry | FPM |
Water temperature | 2 °C to 40 °C |
Electrical connection | 110 - 240 V / 12 V / 24 V, 50 - 60 Hz |
Dosis | 400 J/m² |
Service life of spotlights | 10,000 h |
Performance | 10 W |
Protection | 10 A |
Throughput | 300 l/h domestic water, 200 l/h emulsions |
Flange distance | 255 mm |
Number of spotlights | 1 |
Dimensions (L x W in mm) | 320 x 42 |

We are happy to advise you!
Do you have questions or would like individual advice? Our expert is available on weekdays.
Opening hours: Mon–Fri 08:00–16:00
+49 3641 327 9697 info@uvconcept.comDownloads
Technical documents for download
Scope of delivery
What is included in the delivery
- UV lamp (10 W)
- User manual
Frequently asked questions
Here you will find answers to the most frequently asked questions about our product.
A UV-C disinfection system is always the last link in a water treatment chain, as the path to the point of use should be kept as short as possible. In particular, water filters offer ideal conditions for colonization by bacteria. The freshly disinfected water would therefore become contaminated again if it were to continue through the drinking water circuit after passing through the UV-C system. Pressure tanks should also always be installed before the UV-C systems.
Lifetime monitoring is recommended for all users who do not leave the system permanently on. A lamp replacement every 10,000 hours is recommended, as the manufacturer does not guarantee performance beyond that, meaning the amount of UV-C radiation dose necessary for safe disinfection.
For various technical reasons, the UV system should be left on continuously:
1.) The UV system takes about 1 minute to reach full power.
2.) Igniting the lamp requires about as much energy as operating it for two hours.
3.) Each on and off cycle shortens the lifespan.
The correct sizing of the systems is not based on the maximum daily consumption but on the expected maximum peak rate and is therefore dependent on the pump's performance.
It should be noted that no power supplies with pulsed voltage should be used, as this can cause irreparable damage to the system.
Yes, that is possible. However, it is always recommended to use a battery to ignite the lamp. Additionally, a solar regulator should always be used.
No, we recommend flow reactors, as this precisely defines the maximum distance between the water to be disinfected and the UV-C lamp. A tank disinfection system can only ensure complete disinfection if it has a previously calculated circulation. Furthermore, flow reactors are significantly more efficient.
Suitable accessories for PURION 500 PRO Basic







Related posts about the product

Guide to UVC Disinfection: Everything You Need to Know - Drinking Water
Experience the benefits of UVC disinfection: chemical-free, effective, and sustainable – for germ-free and safe drinking water in every household.
Everything important about shipping & purchase
Do you Brauchen Sie Hilfe? We are here for you!