Skip to content
A PURION tropical box with stainless steel housing, water filtration system, and UV-C disinfection unit inside, manufactured by PURION GmbH.

PURION Tropics box

Regular price 17.999,00 kr
Sale price Regular price

Verfügbare Überwachungsstufen für dieses Produkt

Unsere UV-C-Anlagen bieten verschiedene Überwachungsstufen, die auf jede individuelle Anforderung abgestimmt sind.

Ohne Überwachungsstufe

Ohne Überwachungsstufe

  • Manuelle Inspektion erforderlich
  • Unabhängig von Technik nutzbar

Equipped with a 12V pump, lead-gel battery, and a PURION 500 UV-C disinfection system, this tropical box can be used in hard-to-reach areas. The aluminum box with dimensions of 600mm x 270mm x 380mm (L x H x W) is robust, waterproof, and weighs 17kg, making the system easy to transport. This drinking water system can be operated with a 12V power supply, cigarette lighter, or a photovoltaic panel.

Weitere Produkte im Vergleich mit PURION Tropics box

Weitere Produkte im Vergleich mit PURION Tropics box
PURION Tropics box Dieses Produkt
Power consumption 10 W10 W14 W14 W
Pump function YesNoNoYes
Filter details Suspended solids filter (60 µm) Activated carbon filterSuspended solids filter (60 µm) Activated carbon filterSuspended solids filter (60 µm) activated carbon filter Defrosting filter
Water flow rate 400 l/h drinking water400 l/h drinking water400 l/h drinking water400 l/h drinking water
Dimensions 560 x 360 x 240 (L x W x H in mm)640 x 300 x 425 (L x W x H in mm)500 x 450 x 170 (L x W x H in mm)580 x 300 x 420 (L x W x H in mm)
Preis 13.089,00 kr26.303,00 kr12.436,00 kr18.303,00 kr

Häufig gestellte Fragen zu PURION Tropics box

Hier findest du Antworten auf die häufigsten Fragen zu unserem Produkt.

Every UV-C lamp exhibits a technically induced decline in UV-C performance. The manufacturer guarantees that the system will still achieve 60% UV-C performance after 10,000 hours. The specified data for the systems always refer to this 60% performance. However, after 10,000 hours of operation, the performance decline continues to increase. Therefore, the lamp still works, but it no longer produces enough UV-C performance for optimal disinfection results.

Lifespan monitoring is recommended for all users who do not keep the system permanently switched on. A lamp replacement every 10,000 hours is recommended, as the manufacturer does not guarantee performance beyond that, meaning the amount of UV-C radiation dose necessary for safe disinfection.

The correct sizing of the systems is not based on the maximum daily consumption but on the expected maximum peak rate and is therefore dependent on the pump's performance.

It should be noted that no power supplies with pulsed voltage should be used, as this can cause irreparable damage to the system.

Yes, that is possible. However, it is always recommended to use a battery to ignite the lamp. Additionally, a solar controller should always be used.

Hergestellt in Deutschland

Unsere Produkte stehen für höchste Qualität und werden mit Präzision in Deutschland gefertigt.

30 Tage kostenlose Rückgabe

Sie können Ihre Bestellung problemlos innerhalb von 30 Tagen kostenfrei zurücksenden.

Kostenfreie Kundenberatung

Unser erfahrenes Team steht Ihnen jederzeit kostenlos mit Rat und Tat zur Seite.

Offizieller Purion Händler

Vertrauen Sie auf die Garantie und Qualität eines offiziellen Purion-Händlers.

Ihr Berater

Ask a question

Do you have questions or would you like individual advice? Our expert is available on weekdays.

Opening hours: Mon–Fri 08:00–16:00

The fields marked * are required.