4,89 Sehr gut 172 Bewertungen

PURION 2501 DUAL PVC-U OTC Plus


icon
Überwachungsstufe: mit Lebensdauerüberwachung Überwachungsstufen vergleichen

✓ Reliable quality

✓ Access to spare parts

✓ More than 15 years of experience

✓ PVC-U without plasticizer

price:
Special price1.678,95€

incl. VAT Shipping costs will be calculated in the checkout.

steering: standard
Cable extension: Standard 1.5 m
Auf Lager - in 1-3 Werktagen bei Ihnen
PayPal Mastercard Visa American Express Klarna Apple Pay
delivery-truck.png__PID:205694ad-0c81-4c4f-a9a5-a1b05184f262
Schneller & sicherer Versand

box.png__PID:9263acad-f9bf-4141-88c6-71beb2205694
30 Tage kostenlose Rückgabe

Purion Logo neue.png__PID:da4b9263-acad-49bf-a141-88c671beb220
Offizieller Purion Händler 

Description

Hotel systems with a large salt water pool of up to 100m³ offer their customers a valuable, health -promoting product: salt water is gentle on the skin and protects them from drying out. With the PURION 2501 p Dual these advantages for health can be fully exploited. The procedure of the UV-C disinfection with which the PURION 2501 p Dual Working, the water cleans in a natural way. Inside the system, flowing water is targeted with UV-C light, and the DNA compounds of algae and bacteria are dissolved, so that they die. The water is not changed in taste and smell and retains its composition. This is exactly where the disadvantage of cleaning with chlorine is: the water is added to chemicals that are permanently in the water and counteract the health -promoting advantages of salt water. With the help of the PURION 2501 p Dual the salt water pool can be cleaned as healthy as the salt water pool acts on humans. 

This system is designed for a voltage range of 85-264V by a long-voltage operating operating device and can thus be used in many different countries. The system is equipped with a euro plug and can also be used for other types of plugs with an adapter (not included).

This system is suitable for salt water due to the PVC reactor. Since the weld seams of stainless steel are attacked by the salt, there is no alternative to PVC for the salt water area.

In order to keep a pool permanently free from algae, the correct coordination between the pump and UV-C system is necessary. It applies that at least three times the pool content flows through the UV-C system during the day. The maximum flow power of 20m³/h should not be exceeded, because this means that the water is no longer correctly disinfected. In certain cases, it is necessary to run the system longer: This is urgently required, for example, after larger rain or if the water was in the pool over the winter.

Verfügbare Überwachungsstufen für dieses Produkt

Unsere UV-C-Anlagen bieten verschiedene Überwachungsstufen, die auf jede individuelle Anforderung abgestimmt sind.

Ohne Überwachungsstufe

Ohne Überwachungsstufe

  • Manuelle Inspektion erforderlich
  • Unabhängig von Technik nutzbar

ab 1.531,95€

Zum Produkt
Mit Lebensdauer-überwachung

Mit Lebensdauer-überwachung

  • Automatische Laufzeitmessung der UV-C-Lampe
  • LED-Anzeigen für Status und Voralarme (Grün/Gelb/Rot)
  • Einfache Bedienung ohne manuelles Zählen

ab 1.678,95€

Ausgewählt

Technische Daten

Hier findest du alle technischen Spezifikationen.

Anschluss Adhesive sleeve DN50
Reaktor PVC-U
UVC-Transmission 90% T1 cm
Anlagentyp PURION 2501 PVC-U DUAL
Gewicht 13.2 kg
Dichtung FPM
Wassertemperatur 2 °C to 40 °C
Elektrischer Anschluss 110 - 240 V, 50 - 60 Hz
Dosis 400 J/m²
Strahlernutzungsdauer 10.000 h
Leistung 90 W (2x)
Absicherung 10 A
Flanschabstand 700 mm
Maximaler Betriebsdruck 10 bar
Anzahl der Strahler 2
Dimensionen (L x B in mm) 1000 x 110 (2x)
Support

Wir beraten Sie gerne!

Sie haben Fragen oder wünschen eine individuelle Beratung? Unser Experte ist werktags erreichbar.

Öffnungszeiten: Mo–Fr 08:00–16:00

+49 3641 327 9697 info@uvconcept.com
Anfrage zum Produkt stellen

Downloads

Technische Dokumente zum Herunterladen

Lieferumfang

Was im Lieferumfang enthalten ist

- UV disinfection system
- 2x UV lamp (90 W)
- Operating instructions

Häufig gestellte Fragen

Hier findest du Antworten auf die häufigsten Fragen zu unserem Produkt.

The pool systems of the company PURION are not subject to overheating problems if the UVC system is switched on but there is no water flow.

No. We recommend that the UV system is always operated in combination with the pump so that the full flow is used for disinfection. As the system has a relatively large diameter, there will be no failure if the pump is defective and there is no water flow when the UV lamp is switched on.

For optimum effect, we recommend circulating the entire pool contents at least three times a day. However, the system should be in operation for at least 8 hours a day to ensure sufficient aeration and filtration. the circulation rate therefore depends on the respective performance of the pump and sand filter used. The net output of the pump may be reduced by the length and height of the pipes that have to be overcome: In our compact systems, the pump, sand filter and UVC system are ideally matched and already pre-assembled.

There is a simple calculation for this: the pool contents should flow through the UV-C system at least three times a day in order to kill a large proportion of the algae through appropriate mixing. If algae growth is increased, e.g. during periods of extreme sunlight or after heavy rainfall or a thunderstorm, we recommend adjusting the circulation rate to four times in phases. Regardless of the circulation rate, we recommend operating the system for at least 8 hours a day to ensure sufficient aeration and filtration.

If all three basic recommendations for the use of UV-C systems in the pool area are taken into account, the pool can be operated completely without chlorine. If necessary, the selective use of a biological flocculant is recommended. However, our high-quality UV-C lamps allow a combination of chlorine and UV-C, as no ozone is produced, which would be reactive with chlorine.

The high-quality UV-C lamps of the brand PURION are durable and very powerful. They produce a very high proportion of UV-C. The lamps we use in the pool area are also used in other systems for drinking water treatment. The UV lamps used do not emit any radiation below 250 nm, which prevents the formation of toxic ozone. This means that the PURION can be used in combination with other treatment processes that use chlorine, for example.

No, in our opinion ozone should not be used in the pool area under any circumstances. Ozone is highly toxic. Excess ozone must be destroyed again at great expense, and it is usually unclear how much ozone is left. In addition, ozone reacts with chlorine so that the effect of both processes is greatly reduced. Cheaply produced UV lamps often also emit radiation below 250 nm, which can cause ozone to form. This is the case with PURION excluded.

Each UV-C lamp has a technically induced drop in UV-C output. The manufacturer guarantees that the system will still achieve 60% UV-C output after 10,000 hours. The data specified for the systems always refer to this 60% output. However, from a running time of 10,000 hours, the drop in output continues to increase. This means that the lamp is still working, but there is no longer enough UV-C output for an optimum disinfection result.

Lifetime monitoring is recommended for all users who do not leave the system switched on permanently. It is recommended that the lamp is replaced every 10,000 hours, as the manufacturer does not guarantee its performance beyond this, i.e. the amount of UV-C radiation required for safe disinfection.

Passende Beiträge zum Produkt

Zuletzt angesehen

Alles Wichtige zu Versand & Kauf

Benötigst du Hilfe? Wir sind für dich da!